Fluke 353 True RMS 2000 A Clamp Meter
Fluke 353 True RMS clamp meter is reliable, rugged & can be used for measuring voltage & resistance accurately.
Versatile and rugged tool for applications with high currents
Confidently take reliable readings with the True RMS, Fluke 353 digital clamp meter; the tools of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.
Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads.
Features :
Reliably handle a wide range of high-current applications with 2000 A AC + DC true-rms, 1400 A ac, and 2000 A DC
The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
CAT IV 600 V, CAT III 1000 V rating for added user protection
In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
Accurately measure frequency up to 1 kHz for optimum troubleshooting
Quickly analyze readings using the MIN, MAX, and AVG functions
A large backlit display allows for easy visibility in low-lit areas
Use the display hold feature to capture readings even when the display cannot be viewed
Use the low-pass filter to smooth out noisy loads and stabilize readings
Electrical Specifications Current measurement DC and AC 10 Hz to 100 Hz Range 40 A / 400 A / 2000 A / 1400 AC RMS Resolution 10 mA / 100 mA / 1 A Accuracy A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits Trigger level for Inrush 0.50 A / 5.0 A / 5 A Trigger level for Hz filter OFF 2.50 A / 2.5 A / 8 A Trigger level for Hz filter ON 0.50 A / 2.5 A / 8 A Crest Factor (50/60 Hz) Range 40 A / 400 A / 2000 A / 1400 AC RMS Crest Factor1 2 @ 33 A, 2.4 @ 27 A 2 @ 330 A, 2.4 @ 270 A 2 @ 1000 A, 2.4 @ 833 A Current measurement AC 100.1 Hz to 1 kHz Range 40 A / 400 A / 2000 A; 1400 AC RMS Resolution 10 mA / 100 mA / 1 A Accuracy 10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits Trigger level for Inrush 0.50 A / 5.0 A / 5 A Trigger level for Hz filter OFF 2.50 A / 2.5 A / 8 A Trigger level for Hz filter ON 0.50 A / 2.5 A / 8 A Frequency measurement Measurement range 5.0 Hz to 1 kHz Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) Accuracy – 5.0 Hz to 100 Hz 0.2% + 2 counts Accuracy – 100.1 Hz to 1 kHz 0.5% + 5 counts Trigger level Refer to current and voltage tables 1. Add 2% to error spec for CF > 2 General Specifications Batteries Six 1.5 V AA NEDA 15 A or IEC LR6 Battery life (with typical usage, backlight off) 100 hours Test leads Rated to 1000 V Weight .814 kg (1.8 lb) Jaw size 58 mm (2.28 in) Dimensions (L x W x D) 300 x 98 x 52 mm (12 x 3.75 x 2 in) Safety rating IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III Environmental Specifications Operating temperature 32°F to +122°F (0°C to +50°C) Storage temperature -4°F to 140°F (-20°C to +60°C) Operating humidity 0 to 95% (non-condensing) Operating altitude 2000 m Storage altitude 10,000 m IP rating 42 (indoor use only) Drop test requirements 1 m EMI, RFI, EMC FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3V/m, performance criteria B, EN61325 Temperature coefficients Current 0.1% of reading per °C outside 22°C to 24°C Voltage 0.1% of reading per °C outside 22°C to 24°C