Specification of Wireless High-Low Voltage Clamp Ampere Meter HV1000
Wireless High-Low Voltage Clamp Ampere Meter HV1000
Specifications:
Function: High voltage AC current measurement AC voltage, low current, leakage current measurement, AC current on-line supervision
Power Supply: DC6V Alkaline dry battery (4 x 1.5 V AAA)
Test Method: Clamp CT, integral method
Transmission Method: Wireless transmission, the maximum distance for direct transmission is about 30 m
Display Mode: LCD digital display 4, backlight function, suitable for dark place
LCD Dimension: 47 x 28.5 mm
Meter Dimension: 76 x 255 x 31 mm
Clamp Diameter: φ48mm
Sampling Speed: ± 2 times/second
Range of Measurement: 0.0 mA ~ 1000A (50/60 Hz auto identification)
Accuracy 0.1 mA
Shift: 0.1 mA ~ 1000A automatic shift, 0.1 mA ~ 299mA (CA. 1% ± 3dgts), 0.30 A ~ 31.0 A (± 1.5% ± 5dgts)
Test Accuracy (23 ° ± 5 °, below 80% RH), 50A ~ 199.9 A (± 1.2% ± 5dgts), 200A ~ 600A (± 3% ± 5dgts), 601A ~1000A (± 4% ± 5dgts)
Data Storage: 99 groups, during storage, the symbol "MEM" gives indication, "FULL" mark will flash to indicate the memory has been full.
Storage: Test circuit for the circuit below 60kV (operated with insulation rod)
No Signal Indication: When the receiver has not received transmit signal, it will display "no--" symbol
Auto Shut Down: About 15 minutes after boot, the meter will shut down automatically, in order to decrease the battery consumption.
Battery Voltage When the battery voltage is below 3.0 V, the symbol of battery voltage will show to remind replace battery.
Meter Quality Tester: ± 335 g (including battery), total quality of meters: CA. 2.5 kg (including insulation rod and battery)
Work Temperature and Humidity-10 ° C ~ 40 ° C; below 80% RH
Storage Temperature and Humidity-10 ° C ~ 60 ° C; below 70% RH
Insulated Rod Dimension φ32mm, 1 m/Section (5 sections)
Intension 100kV AC insulation