Ti50 | Ti50 + |
Imaging Performance
Field of View | 18 x 13 º º |
Lens | 13 |
mm Spatial Resolution 1.2 mrad Thermal Sensitivity/NETD 100mK/0.1 ° C at 30 ° C Image Frame Rate full real time 50 Hz 50 Hz/60 Hz full real time Focus Manually Adjust, 30 cm (11.8 ") to infinity Detector 160 x 120, integrates an Uncooled Microbolometer FPA (ULIS France) Spectral Range 8 ~ 14 µm
Imaging Presentation
External Display | 39.5 mm/2.5 º color LCD, Full screen pseudo color | |
Video Output | Not Available |
PAL/NTSC Composite Video
Measurement
Temperature Range | -20 to 350 ° C (-4 to 662 ° F) | -20 to 600 ° C (-40 to 1112 ° F) |
Baisc Accuracy | ± 2 ° C or ± 2% of reading (whichever is greater) | |
MEA |
surement Modes • One moveable spot
• Alarm • Four moveable single spot
• Alarm
• Three moveable areas displaying max, min, avg • One movable area • Isothermal band displaying max, min, avg • One line profile displaying max & min • Temperature difference Display Color 3 Palettes available 11 Palettes available Temperature Unit º º F or C selectable Image Adjusment Auto/Manual gain & brightness Emissivity Correction Megas yialosable 0.01 to 1.00 by 0.01 increments Measurement Features Not available Manual/automatic corrections based on user input for ambient temp,
distance, relative humidity &
Image Storage
Type/Formay | Built-in |
Flash Memory/JPEG (14bit thermal image) Image Storage up to 1000 images up to 2000 images Voice Annotation N/A 40 seconds of digital voice clip stored with each time
Interface
Communication USB 2.0 Laser Locator Class 2, semiconductor diode laser 1mW 635nm/: (red)
Power Source
Power Supply | Built-in rechargeable Lithium-ion battery, field-replaceable |
External Po |
WER Not Available 10 ~ 15VDC Battery Operation Approximately 3 hours Charger 100 ~ 240V AC, 50/60 Hz Power Requirement 7.2 V DC
Environmental
Operati |
NG/Storage Temp. -15 to + 50 ºc (-4 to 122 ° F)/-25 to 60 ° C (-13 to 140 º F) Operating/Storage Humidity ± 90%, non-condensing Enclosure Mounting/Tripod IP 54/¼ "-20
Physical Characteristics
Unit Dimension |
s/Weight 250x100x72mm/9.8 x 3.9 x 2.8 "/680g (1.5 lb) including battery Vibration/Shock Test MIL-STD 810F Method 503.4:
1/2 sine 40 g, 11 ms, 3 shocks per axis
and per the SE MIL-STD 883, Method
condition a:
1/2 sine, 1 ms, 500 g
5 shocks per axis and per the SE
AccessoRIES/Options
Standard Accessories |
• IR Reporter Software • Warranty Card • 2 Rechargeable Batteries • Battery Charger • USB 2.0 Cable • Anti-glare Viewer • Carrying Case & Strap • The Certificate of Conformance of Product. • Manual | • IR Reporter Software |
• Warranty Card
• Battery Charger
• Carrying Case and Strap
• The Certificate of Conformance of Product.
• Video Cable
• Headphones
• Manual
• Anti-glare Viewer
• USB 2.0 Cable
• 2 Rechargeable Batteries Options Not available • Hi-Temperature Lens *
• Power Cable
• Lenses *: 7.5 mm (40 ° x 30 °),
model (9 °