sql

Fluke T5-600-62MAX + 1AC II IR Thermometer Electrical Tester and Voltage Detector Kit

Rp. CALL
Last Updated
21 Sep 2021
Country Origin
Australia
Minimum Order
1
Category
Instrument
Subcategory
Fluke

Specification of Fluke T5-600-62MAX + 1AC II IR Thermometer Electrical Tester and Voltage Detector Kit


Fluke T5-600/62MAX+/1AC II IR Thermometer, Electrical Tester and Voltage Detector Kit



Fluke T5-600 Voltage, Continuity and Current Tester

























































Specifications

Jaw opening

12.9 mm (0.5 in)

Max wire size

1/0 THHN Cable

Current range ac rms

0 to 100.0 A

Accuracy ac current (50/60 Hz)

3 % ± 3 counts

AC Response

Averaging

Voltage range ac

0 to 600 V

Accuracy ac voltage

1.5 % ± 2 counts

Voltage range dc

0 to 600 V

Accuracy dc voltage

1 % ± 1 count

Resistance range

0 to 1000 Ω

Continuity beeper threshold

On at <25 Ω, off at >400 Ω

Volts indicator LED threshold

Guaranteed on by 30 V ac


Fluke 62 MAX+ Infrared Thermometer



































































































Specifications

Temperature Range

-30 °C to 650 °C (-22 °F to 1202 °F)

Accuracy

±1.0 °C or ±1.0% of reading, whichever is greater

-10 °C to 0 °C: ±2.0

-30 °C to -10 °C: ±3.0

Response Time (95%)

Fluke 62 MAX+

<300 ms (95% of reading)

Spectral Response

8 to 14 microns

Emissivity

0.10 to 1.00

Optical Resolution

12:1 (calculated at 90% energy)

Display Resolution

0.1 °C (0.2 °F)

Repeatability of Readings

±0.5% of reading or <±0.5 °C (1 °F), whichever is greater

Power

AA battery

Battery Life

8 hours with laser and backlight on

Physical Specifications

Weight

255 g (8.99 oz)

Size

(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches

Operating Temperature

0 °C to 50 °C (32 °F to 122 °F)

Storage Temperature

-20 °C to 60 °C (-4 °F to 140 °F), (without battery)

Operating Humidity

10 % to 90 % RH non-condensing at 30 °C (86 °F)

Operating Altitude

2000 meters above mean sea level

Storage Altitude

12,000 meters above mean sea level

IP Rating

IP 54 per IEC 60529

Drop Test

3 meters

Vibration and Shock

IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms

EMC

EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance  EN/IEC 61010-1: 2001

Laser Safety  FDA and EN 60825-1 Class II


 



 