Specification of Fluke T + And T + Pro Electrical Tester
Fluke T+ And T+Pro Electrical Tester
Fluke T+ electrical tester is safer than solenoid testers, helps troubleshoot three-phase systems & it complies with NFPA 70E regulations.
Safer than traditional solenoid testers and fully compliant with NFPA 70E*
The T+ Electrical Testers offer all the functionality that electricians look for in volt meters and voltage and continuity testers:
Three ways to detect AC/DC voltage: light, sound, and vibration
Added functionality of a GFCI trip and continuity beeper, plus the convenience of a built-in flashlight
Safer than traditional solenoid testers:
Solid-state tester design
CAT IV 600 V, CAT III 1000 V rated
Complies with NFPA 70E*
Features and benefits of the T+
3 forms of AC/DC voltage indication: light, sound, and vibration for added user protection and convenience
Detect live voltage even when the batteries are dead
Extra heavy-duty, replaceable test leads for more flexibility and durability
CAT IV 600 V, CAT III 1000 V rated for added user protection
Continuity beeper
Bright LED flashlight for work in poorly lit areas
GFCI Trip
On/Off switchable beeper, selectable according to your environment
Compliant with latest NFPA 70E recommendations*
Replaceable test probes for added flexibility and convenience
Convenient probe storage on the back
Probe holder for easier testing
Hazardous voltage warning light for added user protection
Test lead strap included for better test lead management
AC/DC Voltage: 12 V – 600 V on LED bar
Auto-off saves battery power
Specifications
Temperature Operating : -10°C to 55°C (14°F to 131°F)
Storage : -30°C to 60°C (-22°F to 140°F)
Relative humidity : 90% 0°C to 30°C (32°F to 86°F)
75% 30°C to 40°C (86°F to 104°F)
45% 40°C to 50°C (104°F to 122°F)
Altitude Operating : 2,000 m (approx. 6,561.6 ft)
Storage : 10,000 m (approx. 32,808.4 ft)
Battery type/life : AAA (2); 40 hours
Shock, vibration : Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument
Safety : ISA-82.02.01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C22.2 No. 61010-1 Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV
Compliance to : NFPA 70E1
AC bandwidth : 45 Hz to 66 Hz
Maximum working voltage : 1000 V AC/DC
Maximum measurable voltage : 600 V AC/DC
Duty cycle : Indefinitely for voltages up to 240 V
For voltages between 240 V and 600 V the duty cycle is 30 s on / 300 s off
For voltages above 240 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s
Voltage hazard LED : LEDs turn on at voltages > 30 V AC/DC ± 35%
LED voltage indication : levels 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 277 V, 480 V, 600 V
LEDs : LEDs turn on between 90% and 100% of the indicated voltage on the LED, except for the 12 V LED which turns on between 50% and 100%
LCD resolution : 0.1 V for voltages < 50 V, 1 V for voltages ≥ 50 V
GFCI test current : 100 V - 150 V @ 6 mA - 9 mA AC, 150 V - 240 V < 12 mA
Standard input test current : < 5 mA
Size : (H x W x L) 1.3 x 2.15 x 7.6 in (3.3 x 5.46 x 19.3 cm )
Weight : 9.9 oz (0.28 kg)
Model Name Description
Fluke T+ Fluke T+ Electrical Tester
Includes:
User manual
Test lead wrap
TP2 test probes
Fluke T+PRO Fluke T+PRO Electrical Tester
Includes:
User manual
Test lead wrap
TP2 test probes