Specification of Fluke 975V-975-922 922 Airflow Meter Kit And


Fluke 975/975V/922 And 922 Kit  Airflow Meter



Spesifikasi 975 And 975V





























Measured specifications

Temperature

Range:  -20 °C to 50 °C (-5 °F to 122 °F)

Display resolution:  0.1 °C (0.1 °F)

Accuracy:  ± 0.9 °C/± 1.62°F from 40 °C to 60 °C

± 0.5 °C/± 1.00°F from 5 °C to 40 °C

± 1.1 °C/± 1.98 °F from -20 °C to 5 °C

Relative humidity

Range:  10 % to 90 % RH, non-condensing

Display Resolution:  1%

Accuracy:  ± 2 % RH (10 % RH to 90 % RH)

Air velocity

Range:  50.0 fpm to 3000 fpm

0.25 m/sec to 15 m/sec

Display Resolution:  1 fpm (0.005m/sec)

Accuracy:  ±4 % or 4 fpm*

±4 % or 0.02 m/sec* whichever is greater

*Accuracy specification only valid for velocity readings above 50 fpm.

C0

Range:  0 to 500 ppm

Display Resolution:  1 ppm

Accuracy:  ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and

50 % RH

C02

Range:  0 to 5000 ppm

Display Resolution: 

1 ppm

Accuracy:  Warm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm


Spesifikasi 922 And 922 Kit

























Technical Specifications

Air Pressure

Range/Resolution/Accuracy  ± 4000 Pascals / 1 Pascal / ± 1 % + 1 Pascal

± 16 in H2O / 0.001 in H2O / ± 1 % + 0.01 in H2O

± 400 mm H2O / 0.1 mm H2O / ± 1 % + 0.1 mm H2O

± 40 mbar / 0.01 mbar / ± 1 % + 0.01 mbar

± 0.6 PSI / 0.0001 PSI / ± 1 % + 0.0001 PSI

Air Velocity

Range/Resolution/Accuracy  250 to 16,000 fpm / 1 fpm / ± 2.5 % of reading at 2000 fpm (10.00 m/s)

1 to 80 m/s / 0.001 m/s / ± 2.5 % of reading at 2000 fpm (10.00 m/s)

Air Flow (Volume)

Range/Resolution/Accuracy  0 to 99,999 cfm / 1 cfm / Accuracy is a function of velocity and duct size

0 to 99,999 / 1 m3/hr / Accuracy is a function of velocity and duct size

0 to 99,999 l/s / 1 l/s / Accuracy is a function of velocity and duct size

Temperature

Range/Resolution/Accuracy  0 °C to 50 °C / ± 1 % + 2 °C / 0.1 °C

32 °F to 122 °F / ± 1 % + 4 °F / 0.1 °F


 





























































General Specifications

Operating Temperature

0 °C to +50 °C (+32 °F to +122 °F)

Storage Temperature

-40 °C to +60 °C (-40 °F to +140 °F)

Relative Humidity

0% to 90%, non-condensing

IP Rating

IP40

Operating Altitude

2000 m

Storage Altitude

12000 m

EMI, RFI, EMC

Meets requirements for EN61326-1

Vibration

MIL-PREF-28800F, Class 3

Max Pressure at Each Port

10 PSI

Data storage capacity

99 readings

Warranty

2 years

Power, battery life

Four AA batteries

Battery Life

280 hours without backlight, 60 hours with backlight


Model And Accesories


























Model Name

Description

Fluke 975V

AirMeter™ with Velocity

Fluke 975

AirMeter™

Fluke 922

Airflow Meter Includes:


  • Fluke 922 Airflow Meter


  • Two Rubber Hoses


  • Four AA Batteries 1.5 V Alkaline


  • Users Manual


  • Soft Carrying Case



Fluke 922/Kit

Includes:


  • Fluke 922 Airflow Meter


  • 12 inch pitot tube


  • Two Rubber Hoses


  • TPak Magnetic Strip


  • TPak Strap, 9 inches


  • TPak Latch Tab


  • Four AA Batteries 1.5 V Alkaline


  • Users Manual


  • Hard Carrying Case




 


Lihat Selengkapnya

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Request a Quote
Produk Siap di Pesan
Rp 0
1