sql

Fluke 62 MAX + 323-1AC IR Thermometer Clamp Meter and Voltage Detector Kit

Rp. CALL
Last Updated
16 Mar 2023
Country Origin
Australia
Minimum Order
1
Category
Instrument
Subcategory
Fluke

Specification of Fluke 62 MAX + 323-1AC IR Thermometer Clamp Meter and Voltage Detector Kit


Fluke 62 IR Thermometer/323/1AC + MAX, Clamp Meters and Voltage Detector Kit



Fluke 62 MAX + small in size big on toughness.




  • Dust-and waterproof: IP54 rated.


  • Rough: 3 meters (9.8 ft) drop in the test.


  • Ergonomic: completely redesigned to fit the hand more naturally.


  • Distance to venue: 12:1.


  • Double laser: Identifying areas to be measured.


  •  



Large, backlit display: Make data easier to read, even in dark areas.



Fluke 323 True-rms clamp meter, rugged, reliable, right.




  • 400 A ac current measurement.


  • 600 V ac and dc voltage measurements.


  • True-rms ac voltage and current for accurate measurements on non-linear signals.


  • measurement of the resistance of up to 40 kΩ with detection of continuity.


  • Slim, ergonomic design.


  •  



CAT IV 300V/CAT III 600 V safety rating.




  • Fluke 1AC II Voltage Detector VoltAlert ™


  • Voltbeat technology ™ and continuous self-test, so always know it works.


  • After detection, the tip glows and voice pager.


  • detection voltage 1000V ac 90 to.


  • CAT IV 1000 V for additional protection.



Fluke C115 Soft Case

Lightweight soft case for optimal protection



Fluke 62 MAX+ Infrared Thermometer



















































































































Specifications

Temperature Range

-30 °C to 650 °C (-22 °F to 1202 °F)

Accuracy

±1.0 °C or ±1.0% of reading, whichever is greater

-10 °C to 0 °C: ±2.0

-30 °C to -10 °C: ±3.0

Response Time (95%)

Fluke 62 MAX+

<300 ms (95% of reading)

Spectral Response

8 to 14 microns

Emissivity

0.10 to 1.00

Optical Resolution

12:1 (calculated at 90% energy)

Display Resolution

0.1 °C (0.2 °F)

Repeatability of Readings

±0.5% of reading or <±0.5 °C (1 °F), whichever is greater

Power

AA battery

Battery Life

8 hours with laser and backlight on

Physical Specifications

Weight

255 g (8.99 oz)

 

Size

(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches

 

Operating Temperature

0 °C to 50 °C (32 °F to 122 °F)

 

Storage Temperature

-20 °C to 60 °C (-4 °F to 140 °F), (without battery)

 

Operating Humidity

10 % to 90 % RH non-condensing at 30 °C (86 °F)

 

Operating Altitude

2000 meters above mean sea level

 

Storage Altitude

12,000 meters above mean sea level

 

IP Rating

IP 54 per IEC 60529

 

Drop Test

3 meters

 

Vibration and Shock

IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms

 

EMC

EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance

EN/IEC 61010-1: 2001

 

Laser Safety

FDA and EN 60825-1 Class II


Fluke 323 True-rms Clamp Meter

















































































Specifications

AC current

Range

400.0 A

 

Accuracy

2 % ± 5 digits

(45 Hz to 65 Hz)

2.5 % ± 5 digits

(65 Hz to 400 Hz)

AC voltage

Range

600.0 V

Accuracy

1.5 % ± 5 digits

DC voltage

Range

600.0 V

Accuracy

1.0 % ± 5 digits

Resistance

Range

400.0 Ω/ 4000 Ω

Accuracy

1.0 % ± 5 digits

Continuity

≤ 70 Ω

AC response

True-rms

Data hold

Yes

Size

H x W x D (mm)

207 x 75 x 34

 

Max wire diameter

30 mm (600 MCM)

 

Weight

265 g

Category rating

CAT III 600 V

CAT IV 300 V

Warranty

Two-year


Fluke 1AC-II VoltAlert





















































Specifications

Operating principle

Senses the steady state electrostatic field produced by ac voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage.

Voltage sensing ranges

Nominally, 90 V AC to 1000 V AC or 200 V AC to 1000 V AC depending on model, 45 Hz to 405 Hz; also a 20 V to 90 V control circuit model

Detector tip style

Blade or round, depending on model

Light source

One high intensity red LED

Agency Approvals

c CSA us, CE, C-Tick

Safety Rating

1000 V, CAT IV

IP Rating

IP 40

Operating Temperature

-10 °C to 50 °C

Operating humidity ranges

0 % to 95 %  (0 °C to 30 °C)

0 % to 75 %  (30 °C to 40 °C)

0 % to 45 %  (40 °C to 55 °C)

Operating Altitude

3000 meters

Batteries

2 AAA alkaline batteries included


 


Lihat Selengkapnya

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Request a Quote
Produk Siap di Pesan
Rp 0
1