Hover to Zoom
Fluke 62 MAX + small in size big on toughness.
Large, backlit display: Make data easier to read, even in dark areas.
Fluke 323 True-rms clamp meter, rugged, reliable, right.
CAT IV 300V/CAT III 600 V safety rating.
Fluke C115 Soft Case
Lightweight soft case for optimal protection
Fluke 62 MAX+ Infrared Thermometer
Specifications | ||
Temperature Range | -30 °C to 650 °C (-22 °F to 1202 °F) | |
Accuracy |
±1.0 °C or ±1.0% of reading, whichever is greater -10 °C to 0 °C: ±2.0 -30 °C to -10 °C: ±3.0 | |
Response Time (95%) | Fluke 62 MAX+ | <300 ms (95% of reading) |
Spectral Response | 8 to 14 microns | |
Emissivity | 0.10 to 1.00 | |
Optical Resolution | 12:1 (calculated at 90% energy) | |
Display Resolution | 0.1 °C (0.2 °F) | |
Repeatability of Readings | ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater | |
Power | AA battery | |
Battery Life | 8 hours with laser and backlight on | |
Physical Specifications | Weight | 255 g (8.99 oz) |
Size | (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches | |
Operating Temperature | 0 °C to 50 °C (32 °F to 122 °F) | |
Storage Temperature | -20 °C to 60 °C (-4 °F to 140 °F), (without battery) | |
Operating Humidity | 10 % to 90 % RH non-condensing at 30 °C (86 °F) | |
Operating Altitude | 2000 meters above mean sea level | |
Storage Altitude | 12,000 meters above mean sea level | |
IP Rating | IP 54 per IEC 60529 | |
Drop Test | 3 meters | |
Vibration and Shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | |
EMC | EN 61326-1:2006 EN 61326-2:2006 | |
Standards and Agency Approval | Compliance | EN/IEC 61010-1: 2001 |
Laser Safety | FDA and EN 60825-1 Class II |
Fluke 323 True-rms Clamp Meter
Specifications | ||
AC current | Range | 400.0 A |
Accuracy |
2 % ± 5 digits (45 Hz to 65 Hz) 2.5 % ± 5 digits (65 Hz to 400 Hz) | |
AC voltage | Range | 600.0 V |
Accuracy | 1.5 % ± 5 digits | |
DC voltage | Range | 600.0 V |
Accuracy | 1.0 % ± 5 digits | |
Resistance | Range | 400.0 Ω/ 4000 Ω |
Accuracy | 1.0 % ± 5 digits | |
Continuity | ≤ 70 Ω | |
AC response | True-rms | |
Data hold | Yes | |
Size | H x W x D (mm) | 207 x 75 x 34 |
Max wire diameter | 30 mm (600 MCM) | |
Weight | 265 g | |
Category rating |
CAT III 600 V CAT IV 300 V | |
Warranty | Two-year |
Fluke 1AC-II VoltAlert
Specifications | |
Operating principle | Senses the steady state electrostatic field produced by ac voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage. |
Voltage sensing ranges | Nominally, 90 V AC to 1000 V AC or 200 V AC to 1000 V AC depending on model, 45 Hz to 405 Hz; also a 20 V to 90 V control circuit model |
Detector tip style | Blade or round, depending on model |
Light source | One high intensity red LED |
Agency Approvals | c CSA us, CE, C-Tick |
Safety Rating | 1000 V, CAT IV |
IP Rating | IP 40 |
Operating Temperature | -10 °C to 50 °C |
Operating humidity ranges |
0 % to 95 % (0 °C to 30 °C) 0 % to 75 % (30 °C to 40 °C) 0 % to 45 % (40 °C to 55 °C) |
Operating Altitude | 3000 meters |
Batteries | 2 AAA alkaline batteries included |
Untuk keterangan lebih lanjut, silahkan download PDF ini :