Specification of Fluke 62 MAX + 323-1AC IR Thermometer Clamp Meter and Voltage Detector Kit
Fluke 62 IR Thermometer/323/1AC + MAX, Clamp Meters and Voltage Detector Kit
Fluke 62 MAX + small in size big on toughness.
Dust-and waterproof: IP54 rated.
Rough: 3 meters (9.8 ft) drop in the test.
Ergonomic: completely redesigned to fit the hand more naturally.
Distance to venue: 12:1.
Double laser: Identifying areas to be measured.
Large, backlit display: Make data easier to read, even in dark areas.
Fluke 323 True-rms clamp meter, rugged, reliable, right.
400 A ac current measurement.
600 V ac and dc voltage measurements.
True-rms ac voltage and current for accurate measurements on non-linear signals.
measurement of the resistance of up to 40 kΩ with detection of continuity.
Slim, ergonomic design.
CAT IV 300V/CAT III 600 V safety rating.
Fluke 1AC II Voltage Detector VoltAlert ™
Voltbeat technology ™ and continuous self-test, so always know it works.
After detection, the tip glows and voice pager.
detection voltage 1000V ac 90 to.
CAT IV 1000 V for additional protection.
Fluke C115 Soft Case
Lightweight soft case for optimal protection
Fluke 62 MAX+ Infrared Thermometer
Specifications |
Temperature Range |
-30 °C to 650 °C (-22 °F to 1202 °F) |
Accuracy |
±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0 |
Response Time (95%) |
Fluke 62 MAX+ |
<300 ms (95% of reading) |
Spectral Response |
8 to 14 microns |
Emissivity |
0.10 to 1.00 |
Optical Resolution |
12:1 (calculated at 90% energy) |
Display Resolution |
0.1 °C (0.2 °F) |
Repeatability of Readings |
±0.5% of reading or <±0.5 °C (1 °F), whichever is greater |
Power |
AA battery |
Battery Life |
8 hours with laser and backlight on |
Physical Specifications |
Weight |
255 g (8.99 oz) |
|
Size |
(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches |
|
Operating Temperature |
0 °C to 50 °C (32 °F to 122 °F) |
|
Storage Temperature |
-20 °C to 60 °C (-4 °F to 140 °F), (without battery) |
|
Operating Humidity |
10 % to 90 % RH non-condensing at 30 °C (86 °F) |
|
Operating Altitude |
2000 meters above mean sea level |
|
Storage Altitude |
12,000 meters above mean sea level |
|
IP Rating |
IP 54 per IEC 60529 |
|
Drop Test |
3 meters |
|
Vibration and Shock |
IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms |
|
EMC |
EN 61326-1:2006 EN 61326-2:2006 |
Standards and Agency Approval |
Compliance |
EN/IEC 61010-1: 2001 |
|
Laser Safety |
FDA and EN 60825-1 Class II |
Fluke 323 True-rms Clamp Meter
Specifications |
AC current |
Range |
400.0 A |
|
Accuracy |
2 % ± 5 digits
(45 Hz to 65 Hz)
2.5 % ± 5 digits
(65 Hz to 400 Hz) |
AC voltage |
Range |
600.0 V |
Accuracy |
1.5 % ± 5 digits |
DC voltage |
Range |
600.0 V |
Accuracy |
1.0 % ± 5 digits |
Resistance |
Range |
400.0 Ω/ 4000 Ω |
Accuracy |
1.0 % ± 5 digits |
Continuity |
≤ 70 Ω |
AC response |
True-rms |
Data hold |
Yes |
Size |
H x W x D (mm) |
207 x 75 x 34 |
|
Max wire diameter |
30 mm (600 MCM) |
|
Weight |
265 g |
Category rating |
CAT III 600 V
CAT IV 300 V |
Warranty |
Two-year |
Fluke 1AC-II VoltAlert
Specifications |
Operating principle |
Senses the steady state electrostatic field produced by ac voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage. |
Voltage sensing ranges |
Nominally, 90 V AC to 1000 V AC or 200 V AC to 1000 V AC depending on model, 45 Hz to 405 Hz; also a 20 V to 90 V control circuit model |
Detector tip style |
Blade or round, depending on model |
Light source |
One high intensity red LED |
Agency Approvals |
c CSA us, CE, C-Tick |
Safety Rating |
1000 V, CAT IV |
IP Rating |
IP 40 |
Operating Temperature |
-10 °C to 50 °C |
Operating humidity ranges |
0 % to 95 % (0 °C to 30 °C)
0 % to 75 % (30 °C to 40 °C)
0 % to 45 % (40 °C to 55 °C) |
Operating Altitude |
3000 meters |
Batteries |
2 AAA alkaline batteries included |