sql

Fluke 414D-62 MAX + Laser Distance Meter Infrared Thermometer Combo Kit

Rp. CALL
Last Updated
21 Sep 2021
Country Origin
United States
Minimum Order
1
Category
Instrument
Subcategory
Fluke

Specification of Fluke 414D-62 MAX + Laser Distance Meter Infrared Thermometer Combo Kit


Fluke 414D/62 MAX + Laser Distance Meter/Infrared Thermometer Combo Kit



Ideal kit for temperature and distance



The most rugged Fluke 62 MAX+ IR thermometer teamed with the easy to use 414D Laser Distance Meter has everything you need to configure layout and to troubleshoot electrical/HVAC problems quickly. Use the IR thermometer to test for overheating in electrical devices and HVAC components, and use the laser distance meter to determine distance, area, and volume for space configuration.



The 414D reduces errors, saves time and money.




  • The most advanced laser technology for distance measurement.


  • Measures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in).


  • Quick calculation of area (square feet/meters) and volume.


  • Pythagoras function indirectly measures height via two other measurements.


  • Stores up to five measurement results.


  • Battery life of 3000 measurements with automatic shut-off feature.



Fluke 62 MAX+ small in size big on toughness.




  • Dust and water-resistant: IP54 rated.


  • Rugged: 3-meter (9.8-foot) drop tested.


  • Ergonomically designed: Completely redesigned for a more natural hand fit.


  • Distance to spot: 12:1.


  • Dual lasers: Identifies area to be measured.


  • Large, backlit display: Makes data easier to read, even in dark areas.



Fluke 414D Laser Distance Meter


















































































































Distance Measurement

Typical Measuring Tolerance[1]

± 2.0 mm [3]

Maximum Measuring Tolerance[2]

± 3.0 mm [3]

Range at Leica target plate GZM26

50 m / 165 ft

Typical Range[1]

40 m / 130 ft

Range at unfavorable condition[4]

35 m / 115 ft

Smallest unit displayed

1 mm / 1/16 in

∅ laser point at distances

6 /30 / 60 mm

(10 / 50 / 100 m)

Tilt measurement

Measuring tolerance to laser beam[5]

No

Measuring tolerance to housing[5]

No

Range

No

General

Laser class

2

Laser type

635 nm, <1 mW

Protection class

IP40

Automatic laser off

After 90 seconds

Automatic power off

after 180 seconds

Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03

Up to 3,000

measurements

Size (H X W X L)

116mm Length

53mm Width

33mm Depth

Weight (with batteries)

113 g

Temperature range: Storage Operation

-25 °C to +70°C

(-13 °F to +158 °F)


0 °C to +40 °C

(32 °F to +104 °F)



Calibration cycle

Not applicable

Maximum altitude

3000 m

Maximum relative humidity

85% at 20 °F to 120°F

(-7 °C to 50 °C)

Safety

IEC Standard No. 61010-1:2001

EN60825-1:2007 (Class II)

EMC

EN 55022:2010

EN 61000-4-3:2010

EN 61000-4-8:2010

[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C.

[2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 °C to +50 °C.

[3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.

[4] Applies for 100 % target reflectivity, background illumination between 10'000 lux and 30'000 lux.

[5] After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.


 



Fluke 62 MAX+ Infrared Thermometer



















































































































Specifications

Temperature Range

-30 °C to 650 °C (-22 °F to 1202 °F)

Accuracy

±1.0 °C or ±1.0% of reading, whichever is greater

-10 °C to 0 °C: ±2.0

-30 °C to -10 °C: ±3.0

Response Time (95%)

Fluke 62 MAX+

<300 ms (95% of reading)

Spectral Response

8 to 14 microns

Emissivity

0.10 to 1.00

Optical Resolution

12:1 (calculated at 90% energy)

Display Resolution

0.1 °C (0.2 °F)

Repeatability of Readings

±0.5% of reading or <±0.5 °C (1 °F), whichever is greater

Power

AA battery

Battery Life

8 hours with laser and backlight on

Physical Specifications

Weight

255 g (8.99 oz)

 

Size

(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches

 

Operating Temperature

0 °C to 50 °C (32 °F to 122 °F)

 

Storage Temperature

-20 °C to 60 °C (-4 °F to 140 °F), (without battery)

 

Operating Humidity

10 % to 90 % RH non-condensing at 30 °C (86 °F)

 

Operating Altitude

2000 meters above mean sea level

 

Storage Altitude

12,000 meters above mean sea level

 

IP Rating

IP 54 per IEC 60529

 

Drop Test

3 meters

 

Vibration and Shock

IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms

 

EMC

EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance

EN/IEC 61010-1: 2001

 

Laser Safety

FDA and EN 60825-1 Class II


Model And Accesories














Model Name

Description

Fluke 414D/62 MAX+ Kit

Includes:


  • Fluke 414D Laser Distance Meter


  • Fluke 62 MAX+ IR Thermometer




 



 


Lihat Selengkapnya

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Request a Quote
Produk Siap di Pesan
Rp 0
1