Specification of Fluke 376 True RMS AC-DC Clamp Meter with iFlex ®
Fluke 376 True RMS AC-DC Clamp Meter with iFlex ®
You can measure about the awkward sized conductors with Fluke 376 True RMS Clamp Meter with iFlex ®, extending the range of measurements up to 2500 A AC voltage With True RMS. and current measurements, Fluke 376 can read up to 1000 V and 1000 A in both AC and DC modes.
The Fluke 376 is a direct replacement for Fluke 337 Clamp meters.
Security Compliance
EN/IEC 61010-1:2001; CAT III 1000V, CAT IV 600V
Fluke 376 AC/DC clamp meter display provides increased flexibility and increased access wire. Learn more about extending your reach measurements.
Features:
- Flexible iFlex ® now Probes expand the range of measurements up to 2500 A AIR CONDITIONING
- CAT IV 600 V, CAT III 1000 V
- True RMS AC voltage and current for accurate measurements on non-linear signal
- Min, max, r
ATA average and record inflows to catch variations automatically
Integrated low pass filter and a State-of-the-art signal processing allow to use in noisy electrical environments while providing a stable readout Proprietary measurement technology inflows to filter out noise and capture the motor starting current exactly like the protection circuit see it Ergonomic design fits in your hand and can be used whenwearing protective equipment
Large, easy to read screen backlight automatically regulates the correct measurement range so you don't need to change the switch position when taking measurementsElectrical specifications:
AIR CONDITIONING now via Jaw
374 375 and range: 600.0 with
376:999.9 à
Resolution: 0.1 à
Accuracy: 2% ± 5 digits (10-100 Hz)
2.5% ± 5 digits (100-500 Hz)
Crest Factor (50/60 Hz): 3 500 with NAE (375 and 376)
NAE 2.5 600 A
1.42 NAE 1000 A (376)
Add 2% to C.F. managers > 2
When the AIR CONDITIONING via Flexible Probe now
Range: 2500 A
374 and 375 resolution: 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
376:0.1A (999.9 ≤ A)
1 A (≤ 2500 A)
Accuracy: 3% ± 5 digits (5-500 Hz)
Crest Factor (50/60 Hz): 3.0 at 1100 A (375 and 376)
2.5 in 1400 A
1.42 at 2500 A
Add 2% to C.F. managers > 2
The distance from the Optimum i2500-10 Iflex Iflex i2500-18 Error
Flexible probe timep >
0.5 a at (12.7 mm) 1.4 (35.6 mm) ± 0.5%
B at 0.8 (20.3 mm) in 2.0 (50.8 mm) ± 1.0%
1.4 in c (35.6 mm) 2.5 di (63.5 mm) ± 2.0%
measurement uncertainty assumes the main conductor is centered on the optimum position, there is no external magnetic or electric field, and within the range of operating temperature.
DC Current
374 375 and range: 600.0 with
376:999.9 à
Resolution: 0.1 à
Acuratorial: 2% ± 5 digits
AC Voltage
374 375 and range: 600.0 V
376:1000 V
374 and 375 resolution: 0.1 V
376:0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy: 1.5% ± 5 digits (20-500 Hz)
DC Voltage
374 375 and range: 600.0 V
376:1000 V
Resolution 374 and 375:0.1 V
376:0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy: 1% ± 5 digits
MV dc
Range: 375 and 376 500.0 mV
Resolution: 0.1 mV
Accuracy: 1% ± 5 digits
Frequency through the Jaw
375 and 376 range: 5.0-500,0 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% ± 5 digits
Trigger Level 5-10 Hz, ≥ 10 A
10-100 Hz ≥ 5 A
100-500 Hz, ≥ 10 A
Frequency through the Flexible Probe now
375 and 376 range 5.0-500,0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level: 5-20 Hz, ≥ 25 A
20-100 Hz, ≥ 20 A
100-500 Hz, ≥ 25 A
Resistance
374 range: 6000 Ω
375 and 376:60 kΩ
374: resolution 0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
/>
375 and 376:0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
10 Ω (≤ 60 kW)
Accuracy: 1% ± 5 digits
capacitance
Range: 1000 uF
Resolution: 0.1 uF (≤ 100 uF)
1 μ F (≤ 1000 uF)
Accuracy: ± 1% 4 digits
Mechanical specifications
Size (L x W x: H) 246 mm x 83 m x 43 mm
Weight: 388 g
34 mm Jaw opening
/>
Flexible now Probe Diameter: 7.5 mm
Flexible Probe Cable Length now (head to the electronic connector): 1.8 m
Environmental specifications
Operating Temperature: 10 ° C – + 50 ° C
Storage Temp:-40 ° C-+ 60 ° C
Operation Humidity: Non condensing (<10 -="" °="">10>
≤ 90% RH (at 10 ° C-30 ° C)
≤ 75% RH (at 30 ° C-40 ° C)
≤ 45% RH (at 40 ° C-50 ° C)
Operating altitude: 3000 meters
Storage Altitude: 12000 meters
EMC: EN 61326-1:2006
Temperature coefficient: Add 0.1 x accuracy is specified for each degree C above 28 ° C or below 18 ° C
Safety specifications
Safety Compliance: CAN/CSA-C 22.2 No. 61010-1-04
ANSI/UL 61010-1:2004
ANSI/ISA-61010-1 (82.02.01): 2004
EN/IEC 61010-1:2001 for
1000V Measurement Categories (CAT) III
600V Measurement Category IV (CAT)
Pollution Degree 2
EN/IEC 61010-2-032:2002
EN/IEC 61010-031:2002 + A1:2008
Termasu