PT Wijayamas Teknindo

sql
Fluke 373 True RMS AC Clamp Meter
Hover to Zoom

Last Updated
21 Mar 2016
Country Origin
United States
Minimum Order
1

Specification of

Fluke 373 True RMS AC Clamp Meter

Fluke 373 Clamp meters offer increased performance perfect for AC current measurements every situation only. Showing True RMS AC voltage and current measurements, and the measurement of the resistance of up to 6000 Ω with detection of continuity, Fluke 373 is all you need, plus a bit more.

Fluke 373 AC RMS Clamp meters offer increased performance for any AIR CONDITIONING-only current measurement situations. Find out moreabout the benefits of this tool today.

Features and benefits:

  • 600 A ac current measurement with fixed jaw
  • 600 VAC and DC voltage measurement
  • State of the art signal processing allow to use in noisy electrical environments while providing a stable readout
  • CAT IV 300 V, CAT III 600 V
  • True RMS AC voltage and current for accurate measurements on non-linear signal
  • Large, mu
easy-to-read screen backlight automatically regulates the correct measurement range so you don't need to change the switch position when taking measurements

Electrical specifications:

AC Current
Range: 600.0 with
Resolution: 0.1 à
Accuracy: 2% ± 5 digits (48-62 Hz)
Crest Factor: (50/60 Hz) 2.5 NAE 600 A

AC Voltage
Range: 600.0 V
Resolution: 0.1 V
Accuracy: 1.0% ± 5 digits (48-62 Hz)

DC Voltage

Range: 600.0 V
Resolution: 0.1 V
Accuracy: 1% ± 5 digits

Resistance
Range: 600.0 Ω/6000 Ω
Resolution: 0.1 Ω/1 Ω
Accuracy: 1% ± 5 digits
Continuity: Pager 30 Ω

Capacitance
Range: 10.0 100.0-uF/1000 uF
Resolution: 0.1/1 uF uF
Accuracy: 1.9% ± 2 digits

Mechanical specifications
Size: (L x W x H) 232 mm x 85 mm x 45 mm
Weight: 370 g

Environmental specifications
Operating temperature:-10 ° C to + 50 ° C
Storage Temp:-40 ° C to + 60 ° C
Operation Humidity: Non condensing (<10 °="">
≤ 90% RH (at 10 ° C to 30 ° C)
≤ 75% RH (at 30 ° C to 40 ° C)
≤ 45% RH (40 ° C to 50 ° C) (without Kondensasi)
Operating altitude: 3000 meters
Storage Altitude: 12000 meters
EMI, EMC: meets all applicable requirements in EN 61326-1:2006
Temperature coefficient: Add 0.1 x accuracy is specified for each degree C above 28 ° C or below 18 ° C
Safety Compliance: ANSI/ISA S 82.02.01:2004
CAN/CSA-C 22.2 No. 61010-1-04
IEC/EN 61010-1:2001, 6

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Request a Quote
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot