Fluke 1735 Three-Phase Power Loggers
Hover to Zoom

Last Updated
28 Mar 2016
Country Origin
United States
Minimum Order
1

Specification of

Fluke 1735 Three-Phase Power Logger

Specifications
General ¼ VGA Graphic Color transmissive displays 320 x 240 Pixel with additional background lighting and adjustable contrast, text and graphics in color
Quality:  Developed, designed and manufactured according to DIN ISO 9001
Memory:  4 MB Flash memory, 3.5 MB for measuring data
Interface:  RS-232 SUB-D socket; 115.2 k Baud, 8 data bits, no parity, 1 stop bit, firmware updates are possible with the RS- 232 interface (9-pole extension cable)
Sample rate:  10.24 kHz
Line frequency:  50 Hz or 60 Hz, user-selectable, with automatic synchronization
Power supply:  NiMH battery-pack, with ac adapter (15 V to 20 V/0.8 A)
Operation time with battery:  Typical > 12 hours without backlight and > 6 hours with backlight high
Dimensions:  240 mm x 180 mm x 110 mm
Weight:  1.7 kg, including battery
Ambient conditions Working temperature range:  -10 °C to +50 °C
Storage temperature range:  -20 °C to +60 °C
Operating temperature range:  0 °C to +40 °C
Reference temperature range:  23 °C ± 2 °C
Note:  The above terms are defined in European Standards. To calculate the specification at any point in the working temperature range, use the temperature coefficient below.
Temperature coefficient:  ± 0.1 % of the measured value per °C from the reference
Intrinsic error:  Refers to reference temperature, maximum deviation is guaranteed for two years
Operating error:  Refers to operating temperature range, maximum deviation is guaranteed for two years
Climatic class:  C1 (IEC 654-1) -5 °C to +45 °C, 5% to 95% RH, no dew
Housing:  Cycoloy shock and scratch proof thermoplast V0-type (non-flammable) with rubber protection holster
EMC Emission:  IEC/EN 61326-1:1997 class B
Immunity:  IEC/EN 61326-1:1997
Safety Safety:  IEC 61010-1 600 V CAT III, double or reinforced insulation, pollution degree 2
Protection:  IP65; EN60529 (refers only to the main housing without the battery compartment)
RMS values are measured with a 20 ms resolution.
V-rms wye measurement Measuring range:  57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380 V/400 V/417 V/480 V ac
Intrinsic error:  ± (0.2% of measured value + 5 digits)
Operating error:  ± (0.5% of m. v. + 10 digit)
Resolution:  0.1 V
V-rms delta measurement Measuring range:  100 V/115 V/190 V/208 V/220 V/380 V/400 V/415 V/450 V/480 V/600 V/660 V/690 V/720 V/830 V ac
Intrinsic error:  ± (0.2% of m. v. + 5 digit)
Operating error:  ± (0.5 % of m. v. + 10 digit)
Resolution:  0.1 V
A-rms measurement Flexi set I ranges:  15 A/150 A/3000 A rms (at sine)
Current clamp ranges:  1 A/10 A
Resolution:  0.01 A
Ranges  150 A/3000 A and 1 A/10 A
Intrinsic error:  ± (0.5 % of m. v. + 10 digit)
Operating error:  ± (1 % of m. v. + 10 digit)
Ranges  15 A
Intrinsic error:  ± (0.5 % of m. v. + 20 digit)
Operating error:  ± (1 % of m. v. + 20 digit)
The errors of the current probes are not considered.
By using Flexi-Set Flexi Set measuring error:  ± (2% of m. v. + 10 digit)
Position influence:  ± (3 % of m. v. + 10 digit)
CF (typical):  2.83
Note:  When using Flexi Set please make sure to position the conductor opposite to the Flexi Set-lock
Power measurement (P - Active, S - Apparent, Q- reactive, D - Distorting Measuring range:  see V rms and A rms measurement
Power errors are calculated by adding the errors of voltage and current
Additional error due to power factor PF
Specified error x (1-[PF])
Maximum range with voltage range 830 V delta-connection and 3000 A current range is 2.490 MW, higher displayed values possible when using PTs and CTs with ratio feature
Intrinsic error:  ± (0.7 % of m.v. +15 digit)
Resolution:  1 kW
Operating error:  ± (1.5 % of m.v. + 20 digit)
Typical range with voltage range 230 V wye connection and 150 A current range is 34.50 KW.
Intrinsic error:  ± (0.7 % of m.v. +15 digit)
Resolution:  1 W to 10 W
Operating error:  ± (1.5 % of m.v. + 20 digit)
The errors of the current sensors themselves have not been considered.
Energy measurement (kWh, KVAh, kVARh) Intrinsic error:  ± (0.7 % of m.v.+ F variation error* + 15 digit)
Resolution:  1 W to 10 W
Operating error:  ± (1.5 % of m.v. + F variation error* + 20 digit)
*Frequency variation error
PF (Power factor) Range:  0.000 to 1.000
Resolution:  0.001
Accuracy:  ±1 % of full scale
Frequency measurement Measuring range:  46 Hz to 54 Hz and 56 Hz to 64 Hz
Intrinsic error:  ± (0.2 % of m. v. + 5 digit)
Operating error:  ± (0.5 % of m. v.+ 10 digit)
Resolution:  0.01 Hz
Harmonics Measuring range:  To 50th harmonic (< 50 % of nom)
Accuracy Vm, Im, THDV, THDI:  IEC 61000-4-7:2002, Class II
Vm ≥ 3% Vn:  ± 5% Vm
Vm < 3 % Vnom:  ±0.15% Vnom
Im ≥ 10 % Inom:  ± 5% Im
Im < 10 % Inom:  ± 0 5% Inom
THDV:  for THD < 3% ± 0.15% at Vnom
for THD ≥ 3% ± 5% at Vnom
THDI:  for THD < 10% ± 0.5% at Inom
for THD ≥ 10% ± 5% at Inom
Vnom:  Normal voltage range
Inom:  Nominal current range
Vm and Im are measured values of harmonic m
Events Detection of voltage dips, voltage swells and voltage interruptions with a 10 ms resolution and measuring error of the half period sine wave of rms.
Intrinsic error:  ± (1% of m.v. + 10 digit)
Operating error:  ± (2% of m.v. + 10 digit)
Resolution:  0.1 V

 

Model NameDescription
Fluke 1735Power Logger
Includes:
  • Includes soft carrying case
  • 4 flexible current probes (15 A/150 A/3000 A)
  • Power Log software
  • Voltage leads and clips
  • Color localization set
  • PC interface cable
  • International ac adapter (115/230 V, 50/60 Hz)
  • Printed English manual
  • Multi-language manual CD

 

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Request a Quote
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot