Specification of Fluke 116 HVAC-332 Combo Kit-Includes Multimeter and Clamp Meters
Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter
For the complete solution to HVAC troubleshooting the extra value-packed HVAC Multimeter and Clamp Meter Combo Kit, provides the ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need in a compact carry case.
Fluke116 Digital Multimeter designed by electricians engineered by Fluke.
Fluke 116 HVAC Multimeter with Temperature and Microamps.
TL175 Hard Point Test Lead Set.
TPak ToolPak Magnetic Meter Hanging Strap.
Flexible Cuff Pipe Clamp Thermocouple.
80BK Integrated Temperature Probe.
80AK-A Thermocouple Adapter.
C115 Deluxe Soft Carrying Case with Shoulder Strap.
Fluke 323 True-rms Clamp Meter,rugged,reliable,precise.
400 A ac current measurement.
600 V ac and dc voltage measurement.
True-rms ac voltage and current for accurate measurements on non-linear signals.
Resistance measurement up to 40 kΩ with continuity detection.
Slim, ergonomic design.
CAT IV 300V/CAT III 600 V safety rating.
Fluke 116 HVAC Multimeter with Temperature and Microamps
Specifications |
Maximum voltage between any terminal and earth ground |
600 V |
Surge protection |
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
Display |
6,000 counts, updates 4 per second |
Bar graph |
33 segments, updates 32 per second |
Operating Temperature |
-10 °C to + 50 °C |
Storage Temperature |
-40 °C to + 60 °C |
Battery type |
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
Battery Life |
400 hours typical, without backlight |
Accuracy Specifications |
DC millivolts |
Range |
600.0 mV |
Resolution |
0.1 mV |
Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
DC volts |
Range/Resolution |
6.000 V / 0.001 V |
Range/Resolution |
60.00 V / 0.01 V |
Range/Resolution |
600.00 V / 0.1 V |
Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
Auto volts |
Range |
600.0 V |
Resolution |
0.1 V |
Accuracy |
2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz) |
AC millivolts1 true-rms |
Range |
600.0 mV |
Resolution |
0.1 mV |
Accuracy |
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
AC volts1 true-rms |
Range/Resolution |
6.000 V / 0.001 V |
Range/Resolution |
60.00 V / 0.01 V |
Range/Resolution |
600.0 V / 0.1 V |
Accuracy |
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
Continuity |
Range |
600 Ω |
Resolution |
1 Ω |
Accuracy |
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. |
Ohms |
Range/Resolution |
600.0 Ω / 0.1 Ω |
Range/Resolution |
6.000 kΩ / 0.001 kΩ |
Range/Resolution |
60.00 kΩ / 0.01 kΩ |
Range/Resolution |
600.0 kΩ / 0.1 kΩ |
Range/Resolution |
6.000 MΩ / 0.001 MΩ |
Accuracy |
0.9 % + 1 |
Range/Resolution |
40.00 MΩ / 0.01 MΩ |
Accuracy |
1.5 % + 2 |
Diode Test |
Range/Resolution |
2.000 V / 0.001 V |
Accuracy |
0.9% + 2 |
Capacitance |
Range/Resolution |
1000 nF / 1 nF |
Range/Resolution |
10.00 μF / 0.01 μF |
Range/Resolution |
100.0 μF / 0.1 μF |
Range/Resolution |
9999 μF / 1 μF |
Range/Resolution |
100 μF to 1000 μF |
Accuracy |
1.9% + 2 |
Range/Resolution |
> 1000 μF |
Accuracy |
5% + 20% |
LoZ capacitance |
Range |
1 nF to 500 μF |
Accuracy |
10% + 2 typical |
Temperature2 (Type-K thermocouple) |
Range/Resolution |
-40 °C to 400 °C / 0.1 °C |
Accuracy |
1% + 102 |
Range/Resolution |
-40 °F to 752 °F / 0.2 °F |
Accuracy |
1% + 182 |
AC μamps true-rms (45 Hz to 500 Hz) |
Range/Resolution |
600.0 μA / 0.1 μA |
Accuracy |
1.0% + 2 |
DC μamps |
Range/Resolution |
600.0 μA / 0.1 μA |
Accuracy |
1.0% + 2 |
Hz (V or A input)2 |
Range/Resolution |
99.99 Hz / 0.01 Hz |
Range/Resolution |
999.99 Hz / 0.1 Hz |
Range/Resolution |
9.999 Hz / 0.001 Hz |
Range/Resolution |
50.00 Hz / 0.01 Hz |
Accuracy |
0.1% + 2 |
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
Mechanical & General Specifications |
Size |
167 x 84 x 46 mm (6.57" x 3.31" x 1.82") |
Weight |
550 g |
Warranty |
3 years |
Fluke 323 True-rms Clamp Meter
Specifications |
AC current |
Range 400.0 A |
|
Accuracy |
2 % ± 5 digits
(45 Hz to 65 Hz)
2.5 % ± 5 digits
(65 Hz to 400 Hz) |
AC voltage |
Range |
600.0 V |
Accuracy |
1.5 % ± 5 digits |
DC voltage |
Range |
600.0 V |
Accuracy |
1.0 % ± 5 digits |
Resistance |
Range |
400.0 Ω/ 4000 Ω |
Accuracy |
1.0 % ± 5 digits |
Continuity |
≤ 70 Ω |
AC response |
True-rms |
Data hold |
Yes |
Size |
H x W x D (mm) |
207 x 75 x 34 |
Max wire diameter |
30 mm (600 MCM) |
Weight |
265 g |
Category rating |
CAT III 600 V
CAT IV 300 V |
Warranty |
Two-year |
Model And Accesories
Model Name |
Description |
Fluke 116/323 Kit |
Includes:
Fluke 116 HVAC Multimeter with Temperature and Microamps
Fluke 323 True-rms Clamp Meter
|
Test Leads |
TL225 |
TL225 SureGrip™ Stray Voltage Adapter Test Lead Kit |